Application
The drop wires are designed for extending an open wire line or distribution pairs from a pole or cable terminal to a building. The drop wires are to be installed between distribution point and telephone subscriber premises.
Normes
• CW 1166 (Drop Wires No. 1)
• CW 208 (Drop Wires No. 2)
• CW 1247 (Drop Wires No. 6)
• CW 1320A (Drop Wires No. 8)
Construction
Conductors
Solid cadmium copper of 0.91mm to BS 4807 (Drop Wires No. 1)
Solid copper covered steel of 0.71mm to BS 4807 (Drop Wires No. 2)
Solid copper covered steel of 0.81mm to BS 4807 (Drop Wires No. 6)
Solid cadmium copper of 1.14mm to BS 4807 (Drop Wires No. 8)
Isolation
PVC to BS 6746 T1 (Drop Wires No. 1)
PVC to BS 6746 T2 (Drop Wires No. 2)
PVC to BS 7878 T1 (Drop Wires No. 6)
PVC to BS 6746 T1 (Drop Wires No. 8)
Cable Core Assemblée
Two conductors are extruded parallel, figure-8 type
Electrical Properties
Chef d'orchestre Diamètre nominale |
mm |
0.91 |
0.71 |
0.81 |
1.14 |
BT Drop Fil de référence |
|
No. 1 |
No.2 |
No.6 |
No. 8 |
Conductor Taille |
mm2 |
0.65 |
0.4 |
0.52 |
1.02 |
Minimum de résistance d'isolement @500V DC |
MΩ.km |
24 |
24 |
50 |
24 |
Epaisseur minimale isolation |
mm |
0.75 |
1.02 |
0.8 |
1.52 |
Insulated Conductor Diamètre nominale |
mm |
2.41 |
2.75 |
2.41 |
4.18 |
Mechanical and Thermal Properties
Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 10 x Overall Diameter
Dimensions And Weight
Cable Code |
Nombre de Cores |
Epaisseur minimale isolation mm |
Dimensions Diamètre maximum de câbleX Taille
mm |
Poids nominal kg/km |
0.91mm Conductor, 2.41mm Insulated Wire |
TP1166-Y-1P091-DW1 |
2 |
0.75 |
2.7x5.6 |
25 |
0.71mm Conductor, 2.75mm Insulated Wire |
TP208-Y-1P071-DW2 |
2 |
1.02 |
2.75x6.0 |
20 |
0.81mm Conductor, 2.41mm Insulated Wire |
TP1247-Y-1P081-DW6 |
2 |
0.8 |
2.5x5.4 |
23 |
1.14mm Conductor, 4.18mm Insulated Wire |
TP1320A-Y-1P114-DW8 |
2 |
1.52 |
4.44x9.4 |
34 |